Separator valve

Separator valve is designed for fast overlap of the mixing air-line section in case of stop of the blast supply into the furnace.

It is installed on the horizontal section of the cold blast mixing air-line. 

 

Valve diameter, D, mm

A

B

C

L

H

E

F

K

G

500 700 1000 575 2175 2360 1420 675 1470 780
1200 800 1266 1260 2133 4346 1745 1340 1531 1105

  

Clear diameter, mm 500 1200
Working pressure, MPa 0,52 0,52
Medium temperature, ºC- working 200 200
- the highest short-term 800 800
Drive type  Electromechanical / hand
Valve opening closing time sec 7 14
Drive power, КWt 2,5 3,0
Mass, t 3,5 7,4